Hydrogen (H2) Gas Mass Flow Controllers with Metal bodies
- Environmentally Preferable:
- Leak integrity:
- 1 X 10-9 sccs He (max)
- 1 X 10-9 sccs He (max)
- 1 X 10-9 sccs He (max)
- 1 X 10-9 sccs He (max)
- 1 X 10-9 sccs He (max)
- 1 X 10-9 sccs He (max)
- Max. particulate size:
- 5 µm
- 5 µm
- 5 µm
- 5 µm
- 5 µm
- 5 µm
- Min. operating temperature:
- 0 °C (32 °F)
- 0 °C (32 °F)
- 0 °C (32 °F)
- 0 °C (32 °F)
- 0 °C (32 °F)
- 0 °C (32 °F)
- Width:
- 4,75"
- 4,75"
- 5,25"
- 4,75"
- 4,75"
- 4,75"
- Certification:
- Yes
- Yes
- Yes
- Yes
- Yes
- Yes
- Response time:
- 2000 ms
- 2000 ms
- 2000 ms
- 2000 ms
- 2000 ms
- 2000 ms
- Min. flow rate:
- 0 L/min
- 0 L/min
- 0 L/min
- 0 L/min
- 0 L/min
- 0 L/min
- Max. pressure:
- 1000 psi
- 1000 psi
- 1000 psi
- 1000 psi
- 1000 psi
- 1000 psi
- Max. operating temperature:
- 50 °C (122 °F)
- 50 °C (122 °F)
- 50 °C (122 °F)
- 50 °C (122 °F)
- 50 °C (122 °F)
- 50 °C (122 °F)
- Pressure drop at max. flow:
- 1,06 psid
- 1,06 psid
- 3,5 psid
- 1,06 psid
- 1,06 psid
- 1,06 psid
- Repeatability:
- ±0,25% full-scale
- ±0,25% full-scale
- ±0,25% full-scale
- ±0,25% full-scale
- ±0,25% full-scale
- ±0,25% full-scale
- Accuracy:
- ±1% full-scale
- ±1% full-scale
- ±1% full-scale
- ±1% full-scale
- ±1% full-scale
- ±1% full-scale
- Output:
- 0 to 5 VDC (1000 Ω minimum); linear 4 to 20 mA (50 to 500 Ω loop resistance)
- 0 to 5 VDC (1000 Ω minimum); linear 4 to 20 mA (50 to 500 Ω loop resistance)
- 0 to 5 VDC (1000 Ω minimum); linear 4 to 20 mA (50 to 500 Ω loop resistance)
- 0 to 5 VDC (1000 Ω minimum); linear 4 to 20 mA (50 to 500 Ω loop resistance)
- 0 to 5 VDC (1000 Ω minimum); linear 4 to 20 mA (50 to 500 Ω loop resistance)
- 0 to 5 VDC (1000 Ω minimum); linear 4 to 20 mA (50 to 500 Ω loop resistance)
- Wetted materials:
- Anodized Aluminum, Brass, Viton
- Stainless Steel, Viton
- Anodized Aluminum, Brass, Viton
- Anodized Aluminum, Brass, Viton
- Anodized Aluminum, Brass, Viton
- Anodized Aluminum, Brass, Viton
- O-Ring material:
- Viton
- Viton
- Viton
- Viton
- Viton
- Viton
- Display type:
- 3,5-digit LCD, detachable
- 3,5-digit LCD, detachable
- 3,5-digit LCD, detachable
- 3,5-digit LCD, detachable
- 3,5-digit LCD, detachable
- 3,5-digit LCD, detachable
- Communication interface:
- linear 0 to 5 VDC(1000 Ω minimum load), 4 to 20 mA(50 to 500 Ω loop resistance)
- linear 0 to 5 VDC(1000 Ω minimum load), 4 to 20 mA(50 to 500 Ω loop resistance)
- linear 0 to 5 VDC(1000 Ω minimum load), 4 to 20 mA(50 to 500 Ω loop resistance)
- linear 0 to 5 VDC(1000 Ω minimum load), 4 to 20 mA(50 to 500 Ω loop resistance)
- linear 0 to 5 VDC(1000 Ω minimum load), 4 to 20 mA(50 to 500 Ω loop resistance)
- linear 0 to 5 VDC(1000 Ω minimum load), 4 to 20 mA(50 to 500 Ω loop resistance)
- Process connection:
- 1/4" Compression
- 1/4" Compression
- 1/4" Compression
- 1/4" Compression
- 1/4" Compression
- 1/4" Compression
- Power:
- 12 VDC
- 12 VDC
- 12 VDC
- 12 VDC
- 12 VDC
- 12 VDC
- Height:
- 5,625"
- 5,625"
- 6"
- 5,625"
- 5,625"
- 5,625"
- Warranty:
- 1 year
- 1 year
- 1 year
- 1 year
- 1 year
- 1 year
- Maximum Flow RateGas typeMedia typeLengthPk
- Compact Gas Mass Flow Controller, 0-2 L/min, H2, Aluminum BodyCompact Gas Mass Flow Controller, 0-2 L/min, H2, Aluminum Body32660-662 L/minHydrogenHydrogen25,4 mm11 * 1 ST1 170,00 €NIST traceable
Accessories
Specifications
Leak integrity1 X 10-9 sccs He (max)Max. particulate size5 µmMin. operating temperature0 °C (32 °F)Width4,75"CertificationYesResponse time2000 msMin. flow rate0 L/minEnvironmentally PreferableMax. pressure1000 psiMax. operating temperature50 °C (122 °F)Pressure drop at max. flow1,06 psidRepeatability±0,25% full-scaleAccuracy±1% full-scaleOutput0 to 5 VDC (1000 Ω minimum); linear 4 to 20 mA (50 to 500 Ω loop resistance)Wetted materialsAnodized Aluminum, Brass, VitonO-Ring materialVitonDisplay type3,5-digit LCD, detachableCommunication interfacelinear 0 to 5 VDC(1000 Ω minimum load), 4 to 20 mA(50 to 500 Ω loop resistance)Process connection1/4" CompressionPower12 VDCHeight5,625"Warranty1 yearNIST traceable - Compact Gas Mass Flow Controller, 0-100 cm³/min, H2, Stainless Steel BodyCompact Gas Mass Flow Controller, 0-100 cm³/min, H2, Stainless Steel Body32661-580,1 L/minHydrogenHydrogen25,4 mm11 * 1 ST1 350,00 €NIST traceable
Accessories
Specifications
Leak integrity1 X 10-9 sccs He (max)Max. particulate size5 µmMin. operating temperature0 °C (32 °F)Width4,75"CertificationYesResponse time2000 msMin. flow rate0 L/minEnvironmentally PreferableMax. pressure1000 psiMax. operating temperature50 °C (122 °F)Pressure drop at max. flow1,06 psidRepeatability±0,25% full-scaleAccuracy±1% full-scaleOutput0 to 5 VDC (1000 Ω minimum); linear 4 to 20 mA (50 to 500 Ω loop resistance)Wetted materialsStainless Steel, VitonO-Ring materialVitonDisplay type3,5-digit LCD, detachableCommunication interfacelinear 0 to 5 VDC(1000 Ω minimum load), 4 to 20 mA(50 to 500 Ω loop resistance)Process connection1/4" CompressionPower12 VDCHeight5,625"Warranty1 yearNIST traceable - Compact Gas Mass Flow Controller, 0-30 L/min, H2, Aluminum BodyCompact Gas Mass Flow Controller, 0-30 L/min, H2, Aluminum Body32660-7230 L/minHydrogenHydrogen31,8 mm11 * 1 ST1 380,00 €NIST traceable
Accessories
Specifications
Leak integrity1 X 10-9 sccs He (max)Max. particulate size5 µmMin. operating temperature0 °C (32 °F)Width5,25"CertificationYesResponse time2000 msMin. flow rate0 L/minEnvironmentally PreferableMax. pressure1000 psiMax. operating temperature50 °C (122 °F)Pressure drop at max. flow3,5 psidRepeatability±0,25% full-scaleAccuracy±1% full-scaleOutput0 to 5 VDC (1000 Ω minimum); linear 4 to 20 mA (50 to 500 Ω loop resistance)Wetted materialsAnodized Aluminum, Brass, VitonO-Ring materialVitonDisplay type3,5-digit LCD, detachableCommunication interfacelinear 0 to 5 VDC(1000 Ω minimum load), 4 to 20 mA(50 to 500 Ω loop resistance)Process connection1/4" CompressionPower12 VDCHeight6"Warranty1 yearNIST traceable - Compact Gas Mass Flow Controller, 0-10 cm³/min, H2, Aluminum BodyCompact Gas Mass Flow Controller, 0-10 cm³/min, H2, Aluminum Body32660-520,01 L/minHydrogenHydrogen25,4 mm11 * 1 ST1 170,00 €NIST traceable
Accessories
Specifications
Leak integrity1 X 10-9 sccs He (max)Max. particulate size5 µmMin. operating temperature0 °C (32 °F)Width4,75"CertificationYesResponse time2000 msMin. flow rate0 L/minEnvironmentally PreferableMax. pressure1000 psiMax. operating temperature50 °C (122 °F)Pressure drop at max. flow1,06 psidRepeatability±0,25% full-scaleAccuracy±1% full-scaleOutput0 to 5 VDC (1000 Ω minimum); linear 4 to 20 mA (50 to 500 Ω loop resistance)Wetted materialsAnodized Aluminum, Brass, VitonO-Ring materialVitonDisplay type3,5-digit LCD, detachableCommunication interfacelinear 0 to 5 VDC(1000 Ω minimum load), 4 to 20 mA(50 to 500 Ω loop resistance)Process connection1/4" CompressionPower12 VDCHeight5,625"Warranty1 yearNIST traceable - Compact Gas Mass Flow Controller, 0-200 cm³/min, H2, Aluminum BodyCompact Gas Mass Flow Controller, 0-200 cm³/min, H2, Aluminum Body32660-600,2 L/minHydrogenHydrogen25,4 mm11 * 1 ST1 170,00 €NIST traceable
Accessories
Specifications
Leak integrity1 X 10-9 sccs He (max)Max. particulate size5 µmMin. operating temperature0 °C (32 °F)Width4,75"CertificationYesResponse time2000 msMin. flow rate0 L/minEnvironmentally PreferableMax. pressure1000 psiMax. operating temperature50 °C (122 °F)Pressure drop at max. flow1,06 psidRepeatability±0,25% full-scaleAccuracy±1% full-scaleOutput0 to 5 VDC (1000 Ω minimum); linear 4 to 20 mA (50 to 500 Ω loop resistance)Wetted materialsAnodized Aluminum, Brass, VitonO-Ring materialVitonDisplay type3,5-digit LCD, detachableCommunication interfacelinear 0 to 5 VDC(1000 Ω minimum load), 4 to 20 mA(50 to 500 Ω loop resistance)Process connection1/4" CompressionPower12 VDCHeight5,625"Warranty1 yearNIST traceable - Compact Gas Mass Flow Controller, 0-100 cm³/min, H2, Aluminum BodyCompact Gas Mass Flow Controller, 0-100 cm³/min, H2, Aluminum Body32660-580,1 L/minHydrogenHydrogen25,4 mm11 * 1 ST1 170,00 €NIST traceable
Accessories
Specifications
Leak integrity1 X 10-9 sccs He (max)Max. particulate size5 µmMin. operating temperature0 °C (32 °F)Width4,75"CertificationYesResponse time2000 msMin. flow rate0 L/minEnvironmentally PreferableMax. pressure1000 psiMax. operating temperature50 °C (122 °F)Pressure drop at max. flow1,06 psidRepeatability±0,25% full-scaleAccuracy±1% full-scaleOutput0 to 5 VDC (1000 Ω minimum); linear 4 to 20 mA (50 to 500 Ω loop resistance)Wetted materialsAnodized Aluminum, Brass, VitonO-Ring materialVitonDisplay type3,5-digit LCD, detachableCommunication interfacelinear 0 to 5 VDC(1000 Ω minimum load), 4 to 20 mA(50 to 500 Ω loop resistance)Process connection1/4" CompressionPower12 VDCHeight5,625"Warranty1 yearNIST traceable